UK regulatory planning guide¶
- Status Planning guide, not legal or clinical safety approval
- Last reviewed 2026-08-14
Purpose¶
This guide identifies the decisions a UK deployer must make before using MedTracker with real health data. The repository cannot decide a deployer's legal role, intended purpose, clinical setting, or procurement duties.
Get advice from a qualified data-protection lead, Clinical Safety Officer, and medical-device specialist where the deployment needs it.
Start with intended purpose¶
Write and approve an intended-purpose statement for the deployed product. Keep it aligned with the features, claims, user groups, and clinical setting.
The MHRA states that software may be a medical device when its intended purpose fits the medical-device definition. A record storage or patient-management system does not become a device only because it stores health information. Features that diagnose, recommend treatment, or drive a clinical decision need a fresh classification assessment.
Do not describe MedTracker as a medical device, or as outside medical-device rules, without that assessment.
Data protection¶
Each deployer must identify whether it acts as a controller, processor, or both. It must record the lawful basis and special-category condition for each use of health data.
Complete a Data Protection Impact Assessment when the planned processing is likely to create high risk. The ICO also recommends a DPIA for major projects that use sensitive data or involve vulnerable people. The assessment must cover the real hosting model, users, integrations, retention, support access, and international transfers.
Also prepare:
- a privacy notice and data-subject-rights process;
- records of processing activities;
- processor and subprocessor terms;
- a retention and disposal schedule; and
- incident response and breach assessment procedures.
Check current ICO guidance because UK data-protection law changed after the Data (Use and Access) Act received Royal Assent in 2025.
NHS clinical safety and procurement¶
DCB0129 applies clinical risk management to organisations that develop and maintain health IT systems for use in health and care. DCB0160 covers the deployment and use of those systems. NHS England is reviewing both standards, so a safety case must follow the current release and track later changes.
The supplier and deploying organisation must agree their responsibilities. They should maintain a hazard log and clinical safety case. Release evidence and appointed Clinical Safety Officer oversight are also needed where the standards apply.
NHS procurement may also require:
- Digital Technology Assessment Criteria evidence;
- Data Security and Protection Toolkit evidence;
- accessibility evidence;
- penetration-test and vulnerability-management evidence; and
- interoperability and service-management evidence.
These artefacts do not replace product safety, legal, or security work.
Medical-device path¶
If the intended purpose makes MedTracker medical-device software, confirm the route with an appropriate specialist. The assessment must cover classification, the quality-management system, risk management, clinical evidence, technical documentation, post-market surveillance, registration, and the correct market marking for the target UK nation.
Do not assume a device class or conformity route from this guide. Great Britain and Northern Ireland can have different requirements, and the rules continue to change.
Repository evidence¶
Use repository documents as inputs to a deployment assessment:
- Hosted multi-tenant security gate
- Hosted private beta runbook
- Audit trail
- Audit retention policy
- DPIA audit evidence
- DCB0129 audit evidence
- Accessibility guidelines
- Production environment
Repository evidence proves only the stated code or operational control. It does
not approve a deployment. The hosted private beta remains closed while its
security gate is NO-GO.
Deployment decision record¶
Before go-live, record:
- the approved intended purpose and device-classification advice;
- controller and processor roles, lawful basis, and DPIA approval;
- applicable DCB0129 and DCB0160 responsibilities;
- the completed procurement and accessibility evidence;
- the accepted security and recovery evidence; and
- the people authorised to accept residual clinical, privacy, and operational risk.
Revisit the decision after material feature, hosting, integration, user, or regulatory changes.