Historical unaccounted electricity analysis
The manual electricity report and its Task command have been retired. This page retains the calculation method for interpreting earlier reports; it is not a current operating procedure. Use Home Assistant’s Energy dashboard for current consumption data.
Method #
The report uses the latest complete short-term statistics timestamp as the end of a 24-hour window.
- Whole-home energy is the change in the Octopus electricity meter’s accumulative-consumption statistic.
- Accounted energy is the combined change from the device-consumption sensors configured in the Home Assistant Energy dashboard when this script was created.
- Unaccounted energy is whole-home energy minus accounted energy.
- Residual demand is whole-home current demand minus one non-overlapping power sensor for each accounted load.
- Residual samples are reduced to five-minute medians. This limits false peaks caused by sensors updating at slightly different times.
- Estimated base load is the 10th percentile of the five-minute residual.
- The normal upper bound is the 90th percentile.
- The spike threshold is the 95th percentile. A spike is reported only when two or more consecutive five-minute bins meet that threshold.
The task fails instead of returning a partial result when required entities are missing, energy statistics do not span the complete window, or residual-demand coverage is below 95%.
Limits #
The retired report used a snapshot of the Energy dashboard device list. Its results do not automatically reflect later dashboard or sensor changes.
Unaccounted demand includes genuinely unmetered loads, modelled standby errors, meter precision, and remaining timing differences. A reported spike is a reason to correlate entity state changes; it does not identify a device by itself.